Below freezing, backup heat costs more to run
Electric resistance heat warms the air directly instead of moving it from outside, so it draws more power than the heat pump does on its own.

A pro who works on heat pumps
Your thermostat has an "emergency heat" setting, and it's lit up, or you're wondering when you'd use it. That light usually means your heat pump stopped pulling heat from outside and backup heat took over. This page gets into what that switch does and why it matters here in South Dakota. If the cause turns out to need a closer look, you can get matched with a local contractor who knows these systems.
Connect with a proEmergency heat means your heat pump has stopped moving heat from the outside air and your thermostat has switched over to backup heat to keep the house warm. On a South Dakota heat pump, that backup is usually electric resistance heat built into the air handler, not your gas furnace. The switch happens because the outdoor unit can't pull enough heat from the air when it's frozen over, stuck, or broken down. At low temperatures some ice on the coil is normal and the system clears it on its own. If the emergency heat light is on and stays on, the outdoor unit isn't running right, and the house is heating on backup alone. Backup heat works, but it isn't how the system is meant to run through a South Dakota winter night after night. It's a sign something needs a look, not something to leave switched on and forget about.


Flip the thermostat to emergency heat and it trips a switch inside, sometimes a small jumper marked E or EM HEAT, that tells the system to leave the outdoor unit alone and run the backup heat strip in the air handler instead. That strip doesn't fire all at once. The air handler brings it on in stages, because a heat strip pulls a lot of current and ramping it up keeps the circuit from tripping and keeps the air from coming out scorching. Most heat pump thermostats wire this through its own terminal, often labeled W2 or E, separate from the wire that calls the compressor. While all this is happening, the outdoor unit just sits there. Nothing is working around whatever stopped it, whether that's a frozen coil, a dead fan motor, or a reversing valve stuck in place. It's bypassed, not fixed. Once whatever caused it gets sorted out, switching the thermostat back to normal heat sends the system back to pulling heat from the outdoor coil instead of leaning on the strip.




Electric resistance heat warms the air directly instead of moving it from outside, so it draws more power than the heat pump does on its own.
If the switch stays lit longer than a day or two, the heat pump likely isn't coming back on its own, and the backup coil is carrying the whole house.
You'll notice the house still gets warm, but the outdoor unit looks like it's doing nothing, maybe caked in frost or ice even when it shouldn't be. The air coming out of the vents feels hotter than usual, since it's coming straight off the electric strip instead of the outside air. Your bill is the other clue. Electric resistance heat draws more power than the heat pump alone, and if you've got cheap power here, you may not notice right away, but a system stuck on backup for days will still show up on the statement. Left alone, a stuck reversing valve or a frozen coil doesn't fix itself, and the house keeps running on the more expensive setting until someone looks at it.
Outdoor unit senses it can't pull enough heat from the air
Reversing valve or defrost control fails to respond as expected
Thermostat gets a fault signal from the outdoor unit
Thermostat switches off the compressor and shuts down the outdoor fan



Your request stays with one local pro.
A local pro who knows heat pumps gets your details and gets in touch.
It costs nothing to send, and you don't have to hire anyone.

No frost on the coil, the fan turning, lines running clean to the disconnect. The outdoor unit is pulling heat from the air and sending it inside, and the thermostat has no reason to call for backup.

Dust built up on the coil, weather working on the cabinet, the fan not moving air the way it should. A unit in this shape struggles to pull heat from outside, and that's what pushes the thermostat to emergency heat.


At 13.32 cents a kilowatt-hour, running the backup heat strips for a few days while a part gets fixed won't wreck your bill. Leaving the thermostat on emergency heat for weeks is where the cost adds up, since that coil is heating the air directly instead of your heat pump moving it.
EIA-861 2025 statewide residential average
That light means the backup coil is carrying the house instead of the outdoor unit. It is not a mystery and it is not an emergency in the way the word suggests. It is the system telling you the heat pump side has a problem, and asking the backup heat to cover until it's fixed.
A day or two on emergency heat while someone sorts out the outdoor unit won't do much to your bill at South Dakota power prices. What matters more is not letting it sit. The switch is a signal, and the longer it stays lit, the longer that coil keeps working harder than it has to.
Whoever looks at your system should be someone who already knows what makes a heat pump land on backup heat in a South Dakota winter, because they've opened up outdoor units with the exact same problem more than once this season. That's the kind of contractor requesting a repair here connects you with: one licensed contractor working near you, not a handful of companies calling about the same job.
You don't need to diagnose the reversing valve or the defrost board yourself. You need the house warm while someone who works on this equipment all winter figures out why the outdoor unit stopped pulling its weight, and gets it back to doing the job the backup coil was only ever meant to cover for.

Your request goes to one pro, not a list of companies.