Two systems, one thermostat
A dual fuel setup wires the heat pump and the gas furnace to the same control. You never touch a switch. The system picks whichever one makes sense for the temperature outside.

Finding a pro stops being your job
A heat pump works harder once temperatures drop below freezing, and South Dakota gets plenty of nights colder than that. This page gets into what a heat pump can handle on its own, when it needs backup, and what a system built for this climate looks like. Send the form and a licensed local installer takes it from there.
Hand it overA heat pump loses capacity as the outdoor temperature drops, and on the coldest nights here, well below zero, most heat pumps can't pull enough heat from that air to keep your house warm on their own. That's not a defect. It's how the refrigerant cycle works: the colder the air outside, the less heat there is in it to move indoors. Since most homes in South Dakota heat with gas, the common setup pairs the heat pump with a gas furnace as backup. The heat pump carries the milder stretches of fall and spring and the early part of winter, and the furnace takes over once it gets too cold for the heat pump to keep up efficiently. Sized and installed for this climate, a heat pump still cuts into how many months the furnace has to run. Sized wrong, or installed without that backup, it leaves you cold on the nights you need heat most.


The heat pump pulls heat out of the outside air.
Colder outdoor air holds less heat for it to pull.
Below a certain temperature, the furnace or strip heat kicks in.
A thermostat or control board decides when to switch over.


A dual fuel setup wires the heat pump and the gas furnace to the same control. You never touch a switch. The system picks whichever one makes sense for the temperature outside.
A contractor who works this equipment every winter here sizes the heat pump and the backup furnace to your home, not a standard chart, so neither one is straining to cover for the other.




If you've got a heat pump paired with a gas furnace, you'll notice the furnace carrying more of the load once the cold really sets in. Vents blow warmer when the furnace is running than when the heat pump handles it alone. Some homeowners notice the outdoor unit running nonstop on a single-digit night, air coming out of the vents, but the house still losing a degree or two anyway. If the heat pump is running alone with no backup and no sign of a furnace taking over, the house will keep slipping below the thermostat setting on the coldest stretches. That's not something to wait out. It means the house is cold and the equipment is maxed out with nothing left to call on.

A heat pump outside the wall, mulch and grass trimmed around it, the disconnect box mounted clean on the siding. Nothing straining. Air moving through the coils, the fan turning steady, pulling what heat it can out of the cold and handing the rest to the furnace.

The same spot, same wall, but the unit's older, the siding gray and worn around it. The conduit still runs to the disconnect box, but a unit this age has usually lost some of the capacity it had new, right when the house needs all of it.


If your heat pump has been struggling to keep the house warm on the coldest nights, or you're putting one in for the first time and want it set up right for winters here, the sizing and the backup heat are the parts that matter most. Get those wrong and you'll notice it in January, not August. A contractor who works on heat pumps in South Dakota winters every year knows which setups hold up at 10 and 20 below and which ones leave a furnace running nonstop to cover for an undersized unit. Send the request and that question becomes someone else's job instead of yours. One local contractor gets it, not a handful, so you're not fielding calls from companies you didn't ask to hear from while you're trying to figure out why the house won't hold heat.

Summer here doesn't lean on a heat pump the way winter does. The dew point averages 56°F across June, July and August, according to NOAA climate data, which is dry enough that the air gives up its heat easily. Your heat pump isn't fighting damp, heavy air to cool the house, so it cycles less and the coil doesn't stay wet as long between runs. That's the easy half of the year for this system. Winter is where the work is, when outdoor air holds little heat to begin with and the heat pump needs help keeping up.
NASA POWER T2MDEW county cells weighted by homes
You've seen it happen on your own system. The thermostat says 70, the heat pump is running non-stop, and the house still feels a few degrees short once it gets cold outside. It's not broken. It's worth knowing what's actually happening inside the unit when that occurs, since it explains why South Dakota winters push a heat pump into territory it can't fully cover alone.
A heat pump moves heat, it doesn't make it. Outside, cold refrigerant runs through the coil and absorbs whatever heat is in the air around it, even air that feels freezing to you. That only works because the refrigerant is colder than the air. As the outdoor temperature drops, that gap shrinks, so there's less heat for the refrigerant to grab on each pass through the coil. The compressor has to work harder to move the same amount of heat indoors, and past a certain point it's pulling from air that just doesn't have much heat left to give. That's the point where a furnace or strip heat has to pick up the difference.

The pad is level, the lines are wrapped clean, and the disconnect box is mounted the way it should be. Shrubs trimmed back, nothing blocking the fan grille. A unit set up like this moves air the way it was designed to, all winter long.

Lines run bare along the foundation, siding stained above the pad, the cabinet showing its age. Nothing here was sized or placed with a South Dakota winter in mind. By the time the cold sets in hard, it's already behind.
At 13.32 cents a kilowatt-hour, the backup heat strip in your system costs more to run than the gas furnace most of your neighbors already have. That's the case for pairing your heat pump with gas instead of leaning on electric strip heat through a cold stretch.
EIA-861 2025 statewide residential average
A heat pump can carry your house through a South Dakota winter, but not by itself. Pair it with gas, size it for your square footage, and it'll run through a cold snap without falling behind. Leave it to handle a stretch below zero on its own, and it loses ground no matter how well it went in. That's the refrigerant cycle doing what it does in cold air. No installer changes that part.
What an installer does change is whether the sizing and the switchover point get set correctly in the first place. That's where a system either carries the load it's supposed to or leaves the furnace doing more work than it should. Someone who installs and services these systems through a South Dakota winter every year has seen where that usually goes wrong, because they're the one who gets the call when a heat pump can't keep up, and they're the one who fixes it when the backup heat was set to kick in too late or too early.
When you send a request through this page, it goes to one contractor, licensed and local, not a batch of companies calling you back at once. You get someone who already knows this climate and this kind of setup, not someone learning it on your house. From there, looking into your system and figuring out what it needs stops being your problem to chase. It's handed off.

Done looking for a heat pump pro